Part Number Hot Search : 
14NM65N P8095 20CTQ040 PT7708C 15KPA22A ESD05CL HC4059 SMF36CA
Product Description
Full Text Search
 

To Download AAT4702IXS-1-T1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 general description the aat4702 smartswitch? is a member of skyworks' application specific power mosfet? (aspm?) product family. this device integrates a high side p-channel mosfet current limiting load switch with a nanopower low dropout (ldo) linear voltage regulator, making the aat4702 ideal for use in load current protected applica- tions that also require a system power supply. the load switch operates with input voltages ranging from 2.4v to 5.5v, making it ideal for 2.5v, 3v, and 5v systems. a fault flag is provided to alert the system to an over- current event. the fault flag has a 5ms blanking time to prevent from reporting false events such as inrush cur- rents during system startup. the load switch current limit is 150ma by default or pro- grammed up to 1a through an external set resistor. the aat4702 ldo linear regulator is designed to deliver a regulated 1.8v supply voltage for load levels up to 100ma. the regulator section may be powered directly from an input source supply or from the load switch out- put. the aat4702 is offered in a pb-free, space-saving 8-pin 2x2mm ftdfn22 package, and is specified for operation over the -40c to +85c ambient temperature range. featuresload switch: ?? 2.4v-5.5v input voltage range ?? 150ma default current limit level ?? 270m ? typical r ds(on) at 2.4v ?? 400ns response to short circuit ?? reverse voltage protection ?? current limit shutdown with output pull down ?? auto restart with 40ms timer ?? 5ms fault blanking timeout ?? under-voltage lockout protection ldo regulator:?? output current up to 100ma ?? 1.8v output voltage with 2% accuracy ?? thermal and short circuit protection ?? active shutdown output pull-down ?? low quiescent current 15 a typical for switch and ldo ?? less than 1 a shutdown current ?? only 1 f ceramic output capacitor required ?? available in ftdfn22-8l package. applications?? cell phones ?? device peripheral ports ?? fingerprint sensors ?? hot swap supplies ?? media players ?? notebook computers typical application 1f 1f 1f in in_reg on / on set out vreg flt gnd aat4702 input enable output ldo reg output fault flag n/c discontinued downloaded from: http:///
2 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 pin descriptions pin # symbol description 1 out current limited p-channel mosfet load switch output. a 0.47 f to 1 f ceramic capacitor connected from out to gnd is recommended for best circuit response. 2 in_reg ldo regulator power input. connect to in to power from a common input supply with the load switch, in which case, bypass with a 1 f ceramic capacitor connected between this pin and ground. alternatively, this pin may be powered from the load switch output by connecting in_reg to out; a 1 f or greater ceramic capacitor should be placed between the out pin and ground for this application 3 vreg ldo regulator output. connect a 1 f or larger capacitor from vreg to gnd for best operating performance. 4 gnd ic ground pin. 5 set current limit set input. connect a resistor from set to ground to program current limit set point for the load switch. or leave open for 150ma default current limit level. 6 flt fault ? ag, open drain output. pull to a logic high level through an external resistor for normal operation. pulled low when fault is present. leave open if unused. 7 on (on) enable input for load switch and ldo regulator. aat4702 -1: active low; pull to a logic low level to enable. aat4702 -2: active high; pull to a logic high level to enable. 8 in input to the p-channel mosfet source. connect a 1 f capacitor from in to gnd. pin configuration ftdfn22-8l (top view) vreg gnd out in_reg fltset inon (on) 3 4 1 2 6 5 8 7 discontinued downloaded from: http:///
3 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 absolute maximum ratings 1 t a = 25c unless otherwise noted. symbol description value units v in, fault in, in_reg, fault to gnd -0.3 to 6 v v on on to gnd -0.3 to v in + 0.3 v out out to gnd -0.3 to v in + 0.3 i out maximum output current 2 internally limited a v esd esd rating, hbm 4000 v t j maximum junction operating temperature -40 to +150 o c t lead maximum soldering temperature (at leads, 10 sec) 300 thermal information 3 symbol description value units ? ja thermal resistance 116.3 o c/w p d maximum power dissipation 4 (t a = 25 o c) 860 mw 1. stresses above those listed in absolute maximum ratings may cause permanent damage to the device. functional operation at conditions other than the operating conditions specified is not implied. only one absolute maximum rating should be applied at any one time. 2. based on long-term current density limitations. 3. mounted on 1oz. copper clad fr4 material printed circuit board. 4. derate 8.6mw/c above 25c. discontinued downloaded from: http:///
4 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 electrical characteristics 1 v in =3.6v;t a = -40 o c to 85 o c unless otherwise noted. typical values are at t a = 25 o c. symbol description conditions min typ max units general v in(sw) input voltage range load switch section 2.4 5.5 v v in(reg) input voltage range stable output 2.4 5.5 for v out within regulation tolerance v out + v do 5.5 % i q operation quiescent current v in = 5v, on = 0v, i out = 0 15 30 a i sd(off) shutdown supply current on = in = 5.5v, v out = 0 1 a load switch r ds(on) pmos on-resistance v out = 5v, t a = 25c 180 280 m ? v out = 3.6v, t a = 25c 220 320 v out = 2.4v, t a = 25c 270 360 i d(off) switch off-leakage on = v in 1 a i lim current limit rising edge; r set = open 100 150 200 ma rset_int current limit internal set resistor 50 k v uvlo under-voltage lockout threshold rising edge 1.8 2.4 v v uvlo_hys under-voltage lockout hysteresis 0.2 v ldo regulator v out dc output voltage v in = 3.6v, i out = 10ma 1.764 1.8 1.836 v i out output current v out = 1.8v 100 ma i sc short-circuit current v out < 0.4v 350 ma ? v out/ v out * ? v in line regulation v in = 4.0 to 5.5v, t a = 25c 0.14 0.4 %/v ? v out /v out load regulation i out = 1ma to 100ma, v out = 1.8v, t a = 25c 1.0 1.65 % v do dropout voltage i out = 100ma, v out = 1.8v 300 mv r ds(reg) regulator pass element on-resistance v in_reg = 3.6v 3.0 ? psrr p ower supply rejection ratio 100hz 50 db t c output voltage temperature coef ? cient 80 ppm/c logic v en(l) on input low voltage 0.4 v v en(h) on input high voltage 2.4v < v in 4.2v 2.0 v 4.2v < v in < 5.5v 2.4 i en on input leakage v en = 5.5v or 0v 0.5 2.0 a t auto auto-restart time 20 40 80 ms t blank over-current blanking time 2 5 10 ms t resp current limit response time v in = 5v 0.4 s t on load switch turn on time v in = 5v; r o = 10 ? ; c o = 1 f1 8 3 5 s t off load switch turn off time v in = 5v; r o = 10 ? ; c o = 1 f3 1 0 s t sd over-temperature shutdown threshold 140 c t hys over-temperature shutdown hysteresis 20 c 1. the aat4702 is guaranteed to meet performance over the -40oc to +85oc operating temperature range and is assured by design, characterization, and correlation with sta- tistical process controls. discontinued downloaded from: http:///
5 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 typical characteristics ? general unless otherwise noted, v in = 3.6v, c in = 1 f, c out = 1 f, c out-ldo = 1 f ,t a = 25c. quiescent current vs. temperature (load switch + ldo) temperature (c) i q (a) -40 -15 10 35 60 85 0 5 10 15 20 25 30 v in = 5.5v v in = 4.2v v in = 3.3v quiescent current vs. input voltage (load switch + ldo) input voltage (v) quiescent current (a) 0.5 1.5 2.5 3.5 4.5 5.5 0 5 10 15 20 25 30 v en(h) and v en(l) vs. input voltage input voltage (v) v en(h) and v en(l) (v) 2 2.5 3 3.5 4 4.5 5 5.5 0.4 0.9 1.4 1.9 2.4 v en(h) v en(l) discontinued downloaded from: http:///
6 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 typical characteristics ? load switch unless otherwise noted, v in = 3.6v, c in = 1 f, c out = 1 f, c out-ldo = 1 f ,t a = 25c. v uvlo vs. temperature (rising and falling) temperature (c) v uvlo (v) -40 -15 10 35 60 85 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 rising edgefalling edge switch off-leakage current vs. temperature temperature (c) i d(off) (a) -40 -15 10 35 60 85 0 0.01 0.02 0.03 0.04 0.05 v in = 5.5v v in = 3.6v v in = 2.4v r ds(on) vs. input voltage input voltage (v) r ds(on) (m) 2 2.5 3 3.5 4 4.5 5 5.5 160 180 200 220 240 260 280 i out = 100ma i out = 50ma r ds(on) vs. temperature temperature (c) r ds(on) (m) -40 -15 10 35 60 85 100 140 180 220 260 300 340 380 v in = 2.4v v in = 3.6v v in = 5.5v current limit vs. output voltage (r set = open) output voltage (v) i lim (ma) 0 1.0 2.0 3.0 4.0 5.0 0.5 1.5 2.5 3.5 4.5 5.5 0 20 40 60 80 100 120 140 160 180 200 r set vs. i lim i lim (ma) r set (k) 150 350 550 750 950 1150 250 450 650 850 1050 1250 1 10 100 1000 discontinued downloaded from: http:///
7 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 typical characteristics ? load switch unless otherwise noted, v in = 3.6v, c in = 1 f, c out = 1 f, c out-ldo = 1 f ,t a = 25c. t blank response (v in = 4v; r set = open) time (4ms/div) flt (5v/div) v out (5v/div) i out (200ma/div) v drive (5v/div) t auto response (v in = 4v; r set = open) time (10ms/div) flt (5v/div) v out (5v/div) i out (200ma/div) v drive (5v/div) t on response (v in = 5v; r l = 40; c l = 0.1f) time (40s/div) on (5v/div) v out (2v/div) i out (50ma/div) t off response (v in = 5v; r l = 40; c l = 1f) time (40s/div) on (5v/div) v out (2v/div) i out (50ma/div) discontinued downloaded from: http:///
8 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 typical characteristics ? ldo regulator unless otherwise noted, v in = 3.6v, c in = 1 f, c out = 1 f, c out-ldo = 1 f ,t a = 25c. output voltage vs. output current output current (ma) output voltage (v) 0 20 40 60 80 100 1.75 1.76 1.77 1.78 1.79 1.8 1.81 1.82 output voltage vs. output current output current (ma) output voltage (v) 100 150 200 250 300 350 400 450 500 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 output voltage vs. input voltage input voltage (v) output voltage (v) 1.7 1.9 2.1 2.3 2.5 1.3 1.4 1.5 1.6 1.7 1.8 1.9 i out = 1ma i out = 10ma i out = 40ma i out = 100ma output voltage vs. input voltage input voltage (v) output voltage (v) 2.5 3 3.5 4 4.5 5 5.5 1.75 1.76 1.77 1.78 1.79 1.8 1.81 1.82 i out = 1ma i out = 10ma i out = 40ma i out = 100ma dropout voltage vs. output current output current (ma) dropout voltage (mv) 0 20 40 60 80 100 0 50 100 150 200 250 300 350 line transient response (v in = 4v->5v->4v; i out = 1ma) time (1ms/div) v out (ac coupled) (200mv/div) i out (10ma/div) v in (2v/div) discontinued downloaded from: http:///
9 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 typical characteristics ? ldo regulator unless otherwise noted, v in = 3.6v, c in = 1 f, c out = 1 f, c out-ldo = 1 f ,t a = 25c. line transient response (v in = 4v->5v->4v; i out = 20ma) time (1ms/div) v out (ac coupled) (200mv/div) i out (20ma/div) v in (2v/div) line transient response (v in = 4v->5v->4v; i out = 100ma) time (1ms/div) v out (ac coupled) (200mv/div) i out (50ma/div) v in (2v/div) load transient response (v in = 4v; i out = 1ma-50ma) time (400s/div) v out (ac coupled) (200mv/div) i out (50ma/div) load transient response (v in = 4v; i out = 1ma-100ma) time (400s/div) v out (ac coupled) (200mv/div) i out (50ma/div) power-up with 1ma load time (200s/div) v out (1v/div) on (2v/div) power-up with 100ma load time (200s/div) v out (1v/div) on (2v/div) discontinued downloaded from: http:///
10 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 functional description the aat4702 is an auto-restarting current limiting load switch with an integrated low dropout linear voltage regulator. the combined function of this device serves to protect system loads or peripheral circuits from over- current conditions while simultaneously supplying an independent regulated voltage for the system. current limiting load switch the aat4702 load switch provides an auto-restarting, reverse current blocking, programmable current limiting and shutdown function. if an applied load exceeds the programmed current limit level, the load switch pass ele- ment will be turned off to isolate the input source from the output and discharge the applied load to ground via an internal nmos switch and a typical 100 resistor. the default current limit (i lim ) set point is 150ma with a ? 50ma tolerance when the set pin is left open (no exter- nal resistor connected). the device may be user pro- grammed to a higher current limit level up to 1a via an external resistor placed between the set pin and ground. when under an output over-current shutdown event, the aat4702 has an auto-restart output polling function that will wake up and re-enable the device every 40ms to check for the continued existence of an over-current condition. if the over-current fault condition remains, the aat4702 will remain in the shutdown state with both the load switch and ldo regulator output pulled low to functional block diagram reverse blocking control timer over-temperature protection 1.2v reference current set 10ms delay outset fault vreg in on / on in_reg gnd discontinued downloaded from: http:///
11 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 ground. when the over-current condition is removed, the aat4702 will automatically resume normal operation. the internal load switch controller provides a fault flag function to alert a system controller to any over current or temperature event. the fault flag output consists of an open drain nmos switch that should be pulled to a logic high level externally through a 10k ? or greater value resistor. the fault flag has a 5ms blanking time feature to guard against reporting false fault conditions, such events could happen during normal circuit start-up. if the fault flag function is not required, the flt pin may be left unconnected. when operating within the limits set by the default or user programmed current limit level, the device over- temperature protection will monitor the internal die tem- perature. if the internal die temperature exceeds 140c, the thermal protection circuit will shut down the load switch to protect the loaded device and the system sup- ply source. the aat4702 load switch and ldo regulator are enabled and disabled through common enable signal at the on (on) pin. the aat4702 provides options for both active low (default) and/or active high operation; refer to the ordering information table to select the desired enable polarity. if the device is operated in an always-on state, the enable function may be terminated to gnd or in respective to which active low or high option is selected. the aat4702 load switch has an under-voltage lockout (uvlo) function, which senses the voltage of the in pin. once v in > v uvlo rising edge (typical 1.8v), the aat4702 will start to operate. for the ldo regulator input in_reg pin, there is no uvlo. low dropout linear regulator the aat4702 ldo linear regulator section has an inde- pendent input pin allowing the regulator to be powered by the load switch output or directly from an input sup- ply. when the enable pin switches to an active state, the ldo regulator output will typically start up and stabilize regulation within 1ms after the load switch. the ldo regulator output is designed and tested to maintain voltage regulation accuracy within a ? 2% toler- ance. voltage regulation accuracy is maintained for input voltage ranges from 5.5v down to a minimum input level (v in_min ) which is defined by the factory trimmed output voltage level (v out ) plus the specified regulator dropout voltage level (v do ), by following the formula: v in_min = v out + v do where: v in_min = minimum input voltage applied to the in_reg pin to maintain regulationv out = factory set ldo regulator output as measured at the vreg pinv do = specified ldo regulator dropout voltage should the ldo regulator input supply fall below the required v in_min level, the output is designed to track the input supply minus a nominal voltage drop across the regulators high-side p-channel mosfet caused by the device's on resistance. the regulator is designed to maintain a stable linear output level of 1.8v for an input supply level down to 2.4v at the specified load current level of 100ma. during ldo regulator shutdown, the vreg output is internally connected to ground via a series resistor and a low-side nmos switch which have a combined imped- ance of 100 ? . the ldo regulator has over-temperature and short-circuit protection independent to the load switch for comprehensive device protection. since the system enable is common to both the ldo regulator and load switch, the ldo regulator will shut down in the event of a fault occurring on the load switch output. for the case of ldo regulator shut down via a load switch fault, the ldo regulator automatically restarts along with the load switch auto-restart system with a 1ms delay. when the ldo regulator is shut down by either the enable function or a fault on the load switch output, the regulator output load will be discharged through the internal active output pull-down circuit. the aat4702 ldo regulator has high power supply ripple rejection (psrr) in addition to fast load and line tran- sient response characteristics. the ldo regulator output has been specifically optimized to function with low cost, low-esr ceramic capacitors. discontinued downloaded from: http:///
12 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 application informationsetting the load switch current limit with no external resistor at the set pin, the default cur- rent limit is 150ma typically set by the internal 50k resister. the current limit function is triggered when the load current reaches 150ma, the load switch and ldo output voltages are shut down; the aat4702 would restart to check if the over-current condition is removed every 40ms. as illustrated in the current limit i lim vs. output voltage curve, the current limit level is kept lower when the output voltage drops; this is helpful to minimize the power dissipation at the load switch to pro- vide safer operation at over-current or output short-cir- cuit condition. if a higher current limit is desired, an external resistor could be placed at the set pin. to determine r set , multi- ply the maximum current drawn by the load by 1.33 (typical i lim = minimum i lim /0.75); this is the typical cur- rent limit value. next, refer to the r set vs. i lim curve and find the r set that corresponds to the typical current limit value. the maximum current is derived by multiply- ing the typical current for the chosen r set in the chart by 1.25. some resistor values are listed in table 1. r set (k ) current limit typ (ma) current limit min (ma) current limit max (ma) 205.1 200 150 250 80.9 250 188 313 49.6 300 225 375 39.6 350 263 438 32.2 400 300 500 27.6 450 338 563 24 500 375 625 20.8 550 413 688 17.6 600 450 750 13.3 700 525 875 10.8 800 600 1000 8.82 900 675 1125 7.88 1000 750 1250 6.87 1100 825 1375 6.17 1200 900 1500 5.54 1300 975 1625 table 1: current limit vs. r set values. example: a usb port requires 500ma. 500ma multiplied by 1.33 is 665ma. from the r set vs. i lim curve, r set should be less than 16.5k . 14.9k is a standard value that is a little less than 16.5k but very close. the chart reads approximately 700ma as a typical i lim value for 14.9k . multiplying 700ma by 0.75 and 1.25 shows that the aat4702 load switch will limit the load current to greater than 525ma but less than 875ma. load switch operation in currentlimit and thermal protection when a heavy load is applied to the output of the aat4702 load switch output, the current limit circuit is triggered when the load current reaches the value of i lim determined by r set . see figure 1 for over-current opera- tion and fault recovery. since the load demands more current than i lim , the voltage at the output drops. when the output voltage drops, the load current is folded back to a lower level. when the overload condition continues for a period longer than the over-current blanking time t blank , the output will be turned off and discharged through the internal n-channel mosfet and resistor. after t auto timeout 40ms, the aat4702 turns on the load switch output to check if the overload condition is removed. if the overload still exists, the output turns off again after t blank timeout. the aat4702 load switch and ldo will continue to cycle on and off until the overload condition is removed. when the die temperature exceeds the over-temperature limit, the aat4702 will shutdown until it has cooled sufficiently, at which point it will start up again. enable input the aat4702 features a load switch and ldo common enable / disable function. this on (on) pin is compatible with cmos logic. active high or active low options are available (see ordering information). in many systems, power planes are controlled by inte- grated circuits which run at lower voltages than the power plane itself. the enable input on (on) of the aat4702 has low and high threshold voltages that accommodate this condition, which could be found in v en(h) and v en(l) vs. input voltage curve. the threshold voltages are compatible with 5v ttl and 2.4v to 5v cmos. when enable is active, the load switch starts up, and the ldo starts up after 1ms. when it is disabled, the device shuts down and the ldo output capacitor is dis- charged through the internal n-channel mosfet and 100 resistor; the load switch is also reverse blocked. discontinued downloaded from: http:///
13 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 vreg i out i out =0 i lim v vreg =0 load switch disabled (out pulled to gnd) v out v out =0 v out recovers on flt on= high on=low v vreg =1.8v v out =v in -i out r ds(on ) i out =0 i out <150ma (default) flt=high flt=low ldo disabled (vreg pulled to gnd) v vreg =0 t blank t auto i out <150ma (default) t blank t blank t auto v vreg =1.8v over-current protection normal operation fault recovers figure 1: aat4702 device output and logic timing diagram for a fault condition and fault recovery. reverse voltage the aat4702 load switch is designed to control the cur- rent flowing from in to out. if a voltage applied to out is greater than the voltage on in, large current may flow if the enable is active. this could cause damage to the aat4702. the on (on) pin can be pulled to low to dis- able the device and prevent current flow from out to in, as the aat4702 load switch could be reverse blocked when on (on) is disabled. input capacitor a 1 f or larger ceramic capacitor is typically recom- mended for c in in most applications. c in should be located as closely to the device in pin as practically pos- sible. c in value greater than 1 f will offer superior input line transient response and will assist in maximizing the power supply ripple rejection. ceramic capacitors are recommended for c in due to their inherent capability over tantalum capacitors to withstand input current surges from low impedance sources such as batteries in portable devices. output capacitora 1 f or larger ceramic capacitor c out1 is typically rec- ommended for the load switch output out pin in most applications. for proper load voltage regulation and operational stabil- ity, a capacitor is required between pins vreg and gnd. the c out2 capacitor connection to the ldo regulator out- put vreg pin and gnd pin should be made as direct as practically possible for maximum device performance. the aat4702 ldo has been specially designed to func- tion with very low esr ceramic capacitors. although the device is intended to operate with these low esr capac- itors, it is stable over a wide range of capacitor esr, thus it will also work with some higher esr tantalum or alu- minum electrolytic capacitors. however, for best perfor- mance, ceramic capacitors are recommended. the value of c out2 typically ranges from 0.47 f to 10 f; however, 1 f is sufficient for most operating conditions. if large output current steps are required by an applica- tion, then an increased value for c out2 should be consid- discontinued downloaded from: http:///
14 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 ered. the amount of capacitance needed can be calcu- lated from the step size of the change in output load current expected and the voltage excursion that the load can tolerate. the total ldo output capacitance required can be calcu- lated using the following formula: c out2 = 15f i v where: i = maximum step in output current v = maximum excursion in voltage that the load can tolerate note that use of this equation results in capacitor values approximately two to four times the typical value needed for an aat4702 at room temperature. the increased capacitor value is recommended if tight ldo output tol- erance must be maintained over extreme operating con- ditions and maximum operational temperature excur- sions. if tantalum or aluminum electrolytic capacitors are used, the capacitor value should be increased to com- pensate for the substantial esr inherent to these capac- itor types. capacitor characteristics ceramic composition capacitors are highly recommended over all other types of capacitors for use with the aat4702. ceramic capacitors offer many advantages over the tantalum and aluminum electrolytic counter- parts. a ceramic capacitors typically has very low esr 10m , is lower cost, has a smaller pcb footprint, and is non-polarized. line and load transient response of the ldo regulator is improved by using low-esr ceramic capacitors. since ceramic capacitors are non-polarized, they are less prone to damage if incorrectly connected. equivalent series resistance (esr) is a very important characteristic to consider when selecting a capacitor. esr is the internal series resistance associated with a capac- itor, which includes lead resistance, internal connections, capacitor size and area, material composition, and ambi- ent temperature. typically, capacitor esr is measured in milliohms for ceramic capacitors and can range to more than several ohms for tantalum or aluminum electrolytic capacitors. ceramic capacitors less than 0.1 f are typically made from npo or c0g materials. npo and c0g materials are typically tight tolerance and very stable over tempera- ture. larger capacitor values are typically composed of x7r, x5r, y5u, and z5v dielectric materials. large ceramic capacitors, typically greater than 2.2 f, are often available in low-cost y5v and z5u dielectrics. these two materials types are not recommended for use with ldo regulators since the capacitor tolerance can vary more than 50% over the operating temperature range of the device. a 2.2 f y5v capacitor could be reduced to 1 f over the full operating temperature range. this can cause problems for circuit operation and stability. x7r and x5r dielectrics are much more desired. the temperature tolerance of x7r dielectric is better than 15%. capacitor area is another contributor to esr. capacitors that are physically large in size will have a lower esr when compared to a smaller sized capacitor of equivalent material and capacitor value. these larger device can also improve circuit transient response when compared to an equal value capacitor in a smaller package size. consult capacitor vendor datasheets carefully when selecting capacitors for use with ldo regulators. ldo short-circuit protectionand thermal protection the aat4702 ldo regulator is protected by both current limit and over-temperature protection circuitry. the internal short-circuit limit is designed to active when the output load demand exceeds the maximum rated output current. if a short-circuit condition were to continually draw more than the current limit threshold, the ldo regulators output voltage will drop to a level necessary to supply the current demanded by the load. under short-circuit or other over-current operating conditions, the output voltage will drop and the aat4702 die tem- perature will rapidly increase. once the devices power dissipation capacity has been exceeded and the internal die temperature reaches approximately 140c at the over-current condition, the ldo thermal protection cir- cuit will actively turn off the ldo regulator output pass element to prevent the possibility of over-temperature damage. the ldo regulator output will remain in a shut- down state until the internal die temperature falls back below the 140c trip point. the interaction between the short-circuit and thermal protection allows the ldo regulator to withstand indefi- nite short-circuit without sustaining permanent damage. discontinued downloaded from: http:///
15 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 ldo no-load stability the aat4702 ldo regulator is designed to maintain out- put voltage regulation and stability under operational no-load conditions. this is an important characteristic for applications where the output current may drop to zero. an output capacitor is required for stability under no- load operating conditions. refer to the "output capacitor" section of this document for recommended typical out- put capacitor values. thermal considerations and high output current applications the aat4702 is designed to deliver a continuous output load current of 1a by the load switch, and 100ma by the ldo regulator under normal operating conditions. the limiting characteristics for the maximum output load safe operating area are essentially package power dis- sipation and the internal preset thermal limit of the device. in order to obtain high operating currents, care- ful device layout and circuit operating conditions need to be taken into account. the following discussions will assume the device is mounted on a printed circuit board utilizing the minimum recommended footprint and the printed circuit board is 0.062-inch thick fr4 material with one ounce copper. at any given ambient temperature (t a ), the maximum package power dissipation can be determined by the fol-lowing equation: p d(max) = t j(max) - t a ja constants for the aat4702 are t j(max) , the maximum junction temperature for the device which is 125c, and the package thermal resistance from junction to ambient ja = 116.3c/w for the ftdfn22-8l. typically, maxi- mum conditions are calculated at the maximum operat- ing ambient temperature where t a = 85c. given t a = 85c, from the above formula, the maximum ftdfn22- 8l package power dissipation is 344mw at t a = 85c. at t a = 25c, the maximum package power dissipation is 860mw. the maximum continuous output current for the aat4702 is a function of the package power dissipation and the input-to-output voltage drop across the ldo regulator and the load switch power consumption. refer to the fol- lowing equation for the total power dissipation: p d(max) = (v in - v out ) i out-ldo(max) + i 2 out-sw(max) r ds(on) + v in i q where:v in = ldo input voltage v out = ldo output voltage i out-ldo(max) = ldo maximum output current i out-sw(max) = load switch maximum output current r ds(on) = load switch on-state resistance, 320m maxi- mum at v in =3.6v i q = operation quiescent current, maximum 30 a for example, if v in = 5v, v out = 1.8v, i out-sw = 200ma and t a = 85 o c, then i out-ldo(max) = 103.5ma. the load switch output short-circuit protection threshold could be set between 150ma to 200ma. if the ldo output load current were to exceed 103.5ma or the ambient tem- perature were to increase, the internal die temperature would increase. if the conditions remained constant and the short-circuit protection did not active, there would be a potential damage hazard to the ldo regulator since the thermal protection circuit would only activate after a short-circuit event or over-current occurred on the ldo regulator output. one solution is to supply the ldo input from the load switch out pin; when the internal die tem- perature reaches the load switch thermal protection point, the load switch output will be disconnected. high peak output current applicationssome applications require the ldo regulator or the load switch to operate at continuous nominal levels with short duration, high-current peaks. the duty cycles for both output current levels must be taken into account. to do so, one would first need to calculate the power dissipa- tion at the nominal continuous level, then factor in the addition power dissipation due to the short duration, high-current peaks. for example, a 1.8v system using an aat4702 operates at a continuous 80ma ldo load current level and has short 150ma current peaks, the load switch load current is 200ma. the ldo current peak occurs for 378 s out of a 4.61ms period. it will be assumed the input voltage is 5.0v. first, the current duty cycle percentage must be calcu- lated: peak current duty cycle (%): = 100 378s/4.61ms = 8.2% discontinued downloaded from: http:///
16 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 the ldo regulator will be under 80ma for 91.8% of the 4.61ms period and have 150ma peaks occurring for 8.2% of the time. next, the continuous nominal power dissipation for the 80ma load should be determined, and then multiplied by the duty cycle to calculate the actual power dissipation over time. p d(max) = (v in - v out ) i out-ldo(max) + i 2 out-sw(max) r ds(on) + v in i q p d(80ma) = (5.0v - 1.8v) 80ma = 256mw p d(91.8%-80ma) = 0.918 p d(80ma) = 0.918 256mw = 235.01mw the power dissipation for an 80ma ldo load occurring for 91.8% of the duty cycle will be 235.01mw. now the power dissipation for the 8.2% of the duty cycle at the 150ma ldo load can be calculated: p d(150ma) = (5.0v - 1.8v) 150ma = 480mw p d(8.2%-150ma) = 0.082 p d(150ma) = 0.082 480mw = 39.36mw the power dissipation for a 150ma ldo load occurring for 8.2% of the duty cycle will be 39.36mw. the last portion is the load switch 200ma power dissipation: p d(200ma) = i 2 out-sw(max) r ds(on) = (200ma) 2 320m = 12.8mw the power dissipation of 200ma load switch current is 12.8mw. finally, the three power dissipation levels can be summed to determine the total true power dissipation under the varied load: = 235.01mw + 39.36mw +12.8mw = 287.17mw p d(total) = p d(91.8%-80ma) + p d(8.2%-150ma) + p d(200ma) the maximum power dissipation for the ftdfn22-8l operating at an ambient temperature of 85c is 344mw. the device in this example will have a total power dis- sipation of 287.17mw. this is within the thermal limits for safe operation of the device. printed circuit board layout recommendations in order to obtain the maximum performance from the aat4702, very careful attention must be considered in regard to the printed circuit board layout. if grounding connections are not properly made, power supply ripple rejection and ldo regulator transient response can be compromised. the load switch and ldo external capacitor c in and c out should be connected as directly to the ground pin. for maximum performance with the aat4702, the ground pin connection should then be made directly back to the ground or common of the source power supply. if a direct ground return path is not possible due to printed circuit board layout limitations, the ldo ground pin should then be connected to the common ground plane in the application layout. discontinued downloaded from: http:///
17 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 application circuits 1f 1f 1f in in_reg on / on set out vreg flt gnd aat4702 input enable output ldo reg output fault flag n/c figure 2: aat4702 application circuit with the load switch and ldo regulator powered from a common input. r set 1f 1f 1f in in_reg on/on set out vreg flt gnd aat4702 10k input enable output ldo reg output fault flag figure 3: aat4702 application circuit with user set (r set ) current limit and fault flag pull-up resistor. discontinued downloaded from: http:///
18 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 evaluation board schematic out 1 in_reg 2 vreg 3 gnd 4 set 5 flt 6 on (on) 7 in 8 u1 aat4702 (ftdfn22-8) v in v out v out_ldo c1 1f c21f c3 1f 10k r1 7.5k r2 1 2 3 jp1 1 23 jp2 1 2 jp3 1 2 jp4 c4dnp figure 4: aat4702 evaluation board schematic. evaluation board layout figure 5: aat4702 evaluation board figure 6: aat4702 evaluation board top layer (not to scale). bottom layer (not to scale). component part number description manufacturer u1 aat4702 auto restarting current limiting load switch with ldo regulator skyworks c1, c2, c3 grm188r61a105ka61 smd, cap ceramic 1 f 0603 x5r 10v 10% murata c4 dnp dnp, do not place r1 chip resistor smd, 10k , 5%, 150mw, 0603 vishay r2 chip resistor smd, 7.5k , 5%, 150mw, 0603 vishay jp1, jp2 connector header 3 pins, pitch 75mil any jp3, jp4 connector header 2 pins, pitch 75mil any shunt shunt for connector any pcb aat4702 evaluation board pcb skyworks table 2: aat4702 evaluation board bill of materials (bom). discontinued downloaded from: http:///
19 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 ordering information package voltage regulator output enable marking 1 part number (tape and reel) 2 ftdfn22-8l 1.8v active low 7cxyy AAT4702IXS-1-T1 ftdfn22-8l 1.8v active high aat4702ixs-2-t1 skyworks green? products are compliant with all applicable legislation and are halogen-free. for additional information, refer to skyworks de?ition of green , document number sq04-0074. package information ftdfn22-8l 2.000 0.050 index area 2.000 0.050 top view 0.500 0.050 detail "a" 0.400 0.050 pin 1 identification 0.000 + 0.100 - 0.000 side view 0.230 0.050 0.750 0.050 bottom view 0.450 0.050 0.250 0.050 detail "a" all dimensions in millimeters. 1. xyy= assembly and date code. 2. sample stock is generally held on part numbers listed in bold . discontinued downloaded from: http:///
20 aat4702 auto-restarting current limiting load switch with ldo regulator data sheet skyworks solutions, inc. phone [781] 376-3000 fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com 201964a skyworks proprietary information products and product information are subject to change without notice. may 17, 2012 copyright ? 2012 skyworks solutions, inc. all rights reserved. information in this document is provided in connection with skyworks solutions, inc. (skyworks) products or services. these materials, including the information contained herein, are provided by sky works as a service to its customers and may be used for informational purposes only by the customer. skyworks assumes no responsibility fo r errors or omissions in these materials or the information contained herein. sky- works may change its documentation, products, services, speci ? cations or product descriptions at any time, without notice. skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for con ? icts, incompatibilities, or other dif ? culties arising from any future changes. no license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. skyworks assumes no liability for any materials, products or informatio n provided here- under, including the sale, distribution, reproduction or use of skyworks products, information or materials, except as may be provided in skyworks terms and conditions of sale. the materials, products and information are provided as is without warranty of any kind, whether express, implied, statutory, or otherwise, including fitness for a particular purpose or use, merchantability, performance, quality or non-infringement of any intellectual property right; all such warranti es are hereby expressly disclaimed. skyworks does not warrant the accuracy or completeness of the information, text, graphics or other items contained within these materials. skyworks shall not be liable for any damages, in- cluding but not limited to any special, indirect, incidental, statutory, or consequential damages, including without limitation, lost revenues or lost profits that may result from the use of the materials or information, whether or not the recipient of materials has been advised of the possibility of such damage. skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the skyworks products could lead to personal injury, death, physical or en- vironmental damage. skyworks customers using or selling skyworks products for use in such applications do so at their own risk and agree to fully indemnify skyworks for any damages resulting from such improper use or sale. customers are responsible for their products and applications using skyworks products, which may deviate from published speci ? cations as a result of design defects, errors, or operation of products outside of pub- lished parameters or design speci ? cations. customers should include design and operating safeguards to minimize these and other risks. skyworks assumes no liabi lity for applications assistance, customer product design, or damage to any equipment resulting from the use of skyworks products outside of stated published speci ? cations or parameters. skyworks, the skyworks symbol, and breakthrough simplicity are trademarks or registered trademarks of skyworks solutions, inc., in the united states and other countries. third-party brands and names are for identi ? cation purposes only, and are the property of their respective owners. additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. discontinued downloaded from: http:///


▲Up To Search▲   

 
Price & Availability of AAT4702IXS-1-T1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X